Excalibur Water Systems 2.0" High Capacity Premium Flow Series Installation Manual

Browse online or download Installation Manual for Water dispensers Excalibur Water Systems 2.0" High Capacity Premium Flow Series. Excalibur Water Systems 2.0" High Capacity Premium Flow Series Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PREMIUM SERIES ELECTRONIC
METERED WATER SOFTENER
Installation Manual
220 Bayview Avenue Unit #18
Barrie, Ontario Canada
L4N 4Y8
www.excaliburwater.com
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Installation Manual

PREMIUM SERIES ELECTRONIC METERED WATER SOFTENER Installation Manual 220 Bayview Avenue Unit #18 Barrie, Ontario Canada L4N 4Y8 www.ex

Page 2 - INSTALLATION MANUAL

WATER SOFTENER PROGRAMMING SETTINGS Step I: Press next and up simultaneously for 3 seconds. Step II: Set hardness in grains per gallon using the u

Page 3 - REQUIRMENTS

Table 15 Troubleshooting Procedures Problem Possible Cause Solution a. Transformer unplugged a. Connect power 1. Timer does not display time

Page 4

Problem Possible Cause Solution a. Motor not operating a. Replace motor b. No electric power at outlet b. Repair outlet or use working outlet 6

Page 5

EXCALIBUR PREMIUM WATER SOFTENER INSTALLATION MANUAL GENERAL WATER SOFTENER INSTALLATION PROCEDURES The Water Softener control valve, fittings

Page 6

place screwdriver in slots on caps and/or tap with a hammer as this could damage the Premium Water Softener WATER SOFTENER INSTALLATION SITE REQ

Page 7

4. Do not locate the Premium Water Softener where it’s connections including the Water Softener drain and overflow plumbing will be in a room with a

Page 8

backwash flowrate is greater than 7 gallons per minute, use a ¾ inch Water Softener drain line. Where the Water Softener drain line is elevated but em

Page 9

IMPORTANT: Never insert a drain line directly into a drain, sewer line or ptrap. Always allow an air gap between the drain line of the waste water to

Page 10

B) BYPASS POSITION The inlet and outlet handles point to the centre of the bypass valve. The bypass valve is isolated from the water pressure cont

Page 11 - Table 15

D) SHUTOFF POSITION The inlet handles points to the centre of the bypass valve and the outlet points to the direction of flow. The water is shut o

Page 12

THE WATER SOFTNER IS NOW READY FOR TESTING 1. With the bypass valve in the bypass position, manually pour 5 gallons of water into the Water Soften